Wiring

ComfortBridge air handler

1 / 2 + electric heat

1 / 2 + electric heat

AVPTC class. Communicating air handler. No gas, no inducer. Electric heat strips. Outdoor on 1/2 or 24V Y.

Written circuit description only — FieldBench does not redraw maker schematics. Example: R to W closes on a heat call; verify 24V at W1 before you change the IFC.

Open manufacturer PDF

AVPTC + communicating outdoor

ASXC / GSXC / GXV / AXV on 1/2.

AVPTC

No inducer codes. Heat is electric strips.

  • 1DataData
  • 2DataData
  • R24V24V
  • CCommon24V
  • WElectric heat if conventional24V

Landing

  • DataAVPTC 1/2outdoor 1/2

    Data

Prove it

  • CoolCloud sees the air handler and the outdoor.
  • Strip heat is electric — not a gas valve or an inducer E2.

Do not

  • Do not apply AMVC96 gas / inducer charts to this cabinet.

Same 1/2 pair as the furnace. No gas.