Wiring

ComfortLink / AccuLink inverter AC

ComfortLink data pair

ComfortLink data pair

Trane / American Standard XV18 class. Communicating inverter air conditioner. Not XR16 Y/C. Not XV20i (that outdoor has a reversing valve).

Written circuit description only — FieldBench does not redraw maker schematics. Example: R to W closes on a heat call; verify 24V at W1 before you change the IFC.

Open manufacturer PDF

ComfortLink pair

Communicating indoor (XC95m / communicating AH) and ComfortLink stat.

ComfortLink control

English events on the wall control. Data, not Y.

  • DATA+ComfortLinkData
  • DATA−ComfortLinkData
  • R24V if the control needs it24V
  • CCommon24V

Communicating indoor

S9V2 24V is a mixed pair — do not diagnose the outdoor with furnace E2.1.

  • DATA+ComfortLinkData
  • DATA−ComfortLinkData

Outdoor drive

Comm LED vs inverter-fault LED. Write both before the disconnect.

  • DATA+ComfortLinkData
  • DATA−ComfortLinkData

Outdoor line — inverter drive

208/230 into the drive. No contactor slam. DC bus can stay live after the disconnect.

  • L1Line to the driveLine
  • L2Line to the driveLine
  • GNDEquipment groundLine

Landing

  • DataStat pairindoor pairoutdoor pair

    Data. Not 24 VAC Y.

  • LineL1 / L2drive

    208/230

Prove it

  • ComfortLink event list. Bus vs drive vs pressure vs sensor.
  • Weigh-in + line-set. Not an XR16 piston SH chart.

Do not

  • Do not apply the XR16 / XR14 Y/C / dual-cap diagram.
  • Do not ohm a defrost sensor on XV18. That is XV20i.

DATA+/DATA− here means the ComfortLink pair on the silk — not a made-up J-number.