Bosch BOVA / IDS
Comm cable + 24V at the AHU
Comm cable + 24V at the AHU
BOVA 2.0 inverter HP. Communicating cable indoor–outdoor. Conventional 24V stat typically at the air handler (Y / B / G / W / C).
Written circuit description only — FieldBench does not redraw maker schematics. Example: R to W closes on a heat call; verify 24V at W1 before you change the IFC.
Open manufacturer PDFBOVA + AHU
IDS / BOVA outdoor with the matching Bosch air handler.
24V stat at the AHU
Y cool, B heat (Bosch often uses B), G, W aux, C.
- R24V hot24V
- CCommon24V
- YCool24V
- BHeat — confirm on THIS AHU24V
- GFan24V
- WAux24V
BOVA outdoor
Communicating cable to the AHU. Photograph the silk. No furnace IFC universal.
- COMMIndoor–outdoor comm on the silkData
Landing
- 24VStat Y/B/G/W/CAHU 24V strip
~24 VAC at the air handler
- DataAHU commBOVA comm
Data cable. Not thermostat wire logic.
Prove it
- 24V at the AHU under Y or B.
- Read the outdoor silk for the comm cable.
Do not
- Do not apply Mitsubishi S1/S2/S3 or Daikin P1/P2.
- Do not throw a dual run cap.
24V lives at the AHU. The outdoor is a drive on a comm cable.