Wiring

EcoNet inverter AC

E1 / E2

E1 / E2

Rheem / Ruud RA19AY Prestige. EcoNet on E1 and E2. RA14AZ / RA16 / RA17 are 24V — different diagrams.

Written circuit description only — FieldBench does not redraw maker schematics. Example: R to W closes on a heat call; verify 24V at W1 before you change the IFC.

Open manufacturer PDF

EcoNet pair

EcoNet control and a communicating indoor.

EcoNet control

E1 / E2 data. R and C still feed the control.

  • R24V hot24V
  • CCommon24V
  • E1EcoNetData
  • E2EcoNetData

Communicating indoor

R96V / matching AH on EcoNet. R96T 24V is a mixed pair.

  • E1EcoNetData
  • E2EcoNetData

Prestige outdoor

Inverter. No dual cap.

  • E1EcoNetData
  • E2EcoNetData

Outdoor line — inverter drive

208/230 into the drive. No contactor slam. DC bus can stay live after the disconnect.

  • L1Line to the driveLine
  • L2Line to the driveLine
  • GNDEquipment groundLine

Landing

  • DataControl E1/E2indooroutdoor

    EcoNet data. Not Y.

  • LineL1 / L2drive

    208/230

Prove it

  • EcoNet control sees the outdoor.
  • E1 / E2 polarity per the silk on THIS outdoor.

Do not

  • Do not apply this to RA14AZ / RA16 / RA17.
  • Do not land 24V Y on E1.

E1 / E2 are the published EcoNet pair.

Plates on this landing