RA19AY
Prestige / Endeavor · inverter AC
Rheem Prestige / Endeavor inverter air conditioner (RA19AY current; RA20 / RA20AY in the field). Outdoor drive + EcoNet when paired. No reversing valve. Charge is weigh-in. Read the refrigerant on the plate — RA20 is often 410A, RA19AY is typically R-454B.
Not RA17 / RA17AZ two-stage. Not RA16 / RA14AZ contactor. Not a heat-pump RP series (RV + defrost).
Drive
Inverter scroll · variable capacity
Bus
EcoNet when the indoor talks; 24V on mixed jobs
Charge
Weigh-in + line-set. Match the nameplate refrigerant.
This board
Prestige outdoor inverter — AC only
- EcoNet events / outdoor drive. Indoor 45/46 is the furnace.
- No dual cap. No defrost.
- RA20 vs RA19AY — same inverter idea, read the refrigerant letter.
EcoNet last events. Drive last-fault if the stat is blank.
Universal swap
Rheem RA19AY outdoor. No furnace IFC universal. Replace the OEM outdoor control / contactor / drive by the silk.
Silk: RA19AY
White-Rodgers
—ICM
—Honeywell
—- Indoor furnace universals (50A55, 50M56U, ICM282B, ICM2811, S9200U). This is not an IFC.
- Do not ‘adapt’ a furnace board to an outdoor inverter, defrost PCB, or contactor.
After you pull the dead card
- 1Photograph the outdoor silk. Indoor 50A55 / ICM282B / S9200U do not belong here.
- 2Contactor units: replace the contactor / cap / HPS — there is no universal outdoor board.
- 3Inverter / communicating outdoors: OEM drive only. There is no White-Rodgers or ICM outdoor universal.
Field wiring
Written landings for Rheem RA19AY. Not a factory schematic.
Rheem / Ruud RA19AY Prestige. EcoNet on E1 and E2. RA14AZ / RA16 / RA17 are 24V — different diagrams.
Written circuit description only — FieldBench does not redraw maker schematics. Example: R to W closes on a heat call; verify 24V at W1 before you change the IFC.
Open manufacturer PDFThis indoor
EcoNet indoor (R96V class). R96T 24V is a mixed pair.
EcoNet pair
EcoNet control and a communicating indoor.
EcoNet control
E1 / E2 data. R and C still feed the control.
- R24V hot24V
- CCommon24V
- E1EcoNetData
- E2EcoNetData
Communicating indoor
R96V / matching AH on EcoNet. R96T 24V is a mixed pair.
- E1EcoNetData
- E2EcoNetData
Prestige outdoor
Inverter. No dual cap.
- E1EcoNetData
- E2EcoNetData
Outdoor line — inverter drive
208/230 into the drive. No contactor slam. DC bus can stay live after the disconnect.
- L1Line to the driveLine
- L2Line to the driveLine
- GNDEquipment groundLine
Landing
- DataControl E1/E2indooroutdoor
EcoNet data. Not Y.
- LineL1 / L2drive
208/230
Prove it
- EcoNet control sees the outdoor.
- E1 / E2 polarity per the silk on THIS outdoor.
Do not
- Do not apply this to RA14AZ / RA16 / RA17.
- Do not land 24V Y on E1.
E1 / E2 are the published EcoNet pair.
Sequence
- 1
Call
Indoor requests capacity. Inverter ramps.
- 2
Protect
HPS / LPS / drive. No defrost.
Faults on this IFC
Step 1, then 2, then 3. Expected reading and the fail branch sit under each check.
Comm
ABCD / outdoor drop
Drive or bus. Wall control loses the outdoor.
1 Let it cool, then read the drive LED
On Rheem RA19AY overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. ABCD landing and polarity, outdoor board power, inverter comms harness.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
2 Voltage and compressor windings
Incoming voltage in range (this plate’s line-voltage code). Compressor windings even, no ground. A shorted compressor will kill a new drive. C still required at the wall control.
Expect: Balanced windings. No winding to ground. Line voltage stable under load.
3 Charge and the drive last
A starved or flooded compressor will overcurrent. Confirm SH/SC and charge weight. Only then condemn the inverter. Indoor must be Infinity-capable. A 24ACC6-style indoor pairing is the wrong mental model.
Expect: Charge on the nameplate. Drive code gone after a cool-down and a clean coil.
HPS / LPS
Pressure protection
Still real on an inverter.
1 Let it cool, then read the drive LED
On Rheem RA19AY overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. Coil, fan, charge by weigh-in — you do not ‘top off’ a Greenspeed.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
2 Voltage and compressor windings
Incoming voltage in range (this plate’s line-voltage code). Compressor windings even, no ground. A shorted compressor will kill a new drive. Outdoor fan that is actually the inverter-driven fan, not a dual-cap PSC motor.
Expect: Balanced windings. No winding to ground. Line voltage stable under load.
3 Charge and the drive last
A starved or flooded compressor will overcurrent. Confirm SH/SC and charge weight. Only then condemn the inverter. Do not use 24ACC6 piston superheat as the pass/fail.
Expect: Charge on the nameplate. Drive code gone after a cool-down and a clean coil.
Inverter
Drive overcurrent / overheat
L5/L4-class faults on the drive.
1 Let it cool, then read the drive LED
On Rheem RA19AY overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. Compressor to ground, heat sink, supply voltage. Weigh-in vs nameplate.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
2 Voltage and compressor windings
Incoming voltage in range (this plate’s line-voltage code). Compressor windings even, no ground. A shorted compressor will kill a new drive. These L-codes do not exist on 24ACC6. If you are looking at a contactor, you are on the wrong outdoor.
Expect: Balanced windings. No winding to ground. Line voltage stable under load.
3 Charge and the drive last
A starved or flooded compressor will overcurrent. Confirm SH/SC and charge weight. Only then condemn the inverter.
Expect: Charge on the nameplate. Drive code gone after a cool-down and a clean coil.
Workflows
Silent RA19AY
Indoor calling, outdoor not ramping.
1 Prove the call and the live code
Drive / EcoNet events. No contactor to chase.
Expect: Write whatever Prestige outdoor inverter — AC only is showing. EcoNet last events. Drive last-fault if the stat is blank.
If fail: No call at the IFC → stat / harness. Do not change gas parts.
2 Isolate the first failed step in the sequence
Weigh-in on the refrigerant that is on THIS plate.
Expect: Protect: HPS / LPS / drive. No defrost.
3 Confirm with a number, then the next part
RP / heat-pump twins have an RV. This AC does not.
Expect: Charge: Recover and weigh. Nameplate + ounces/ft. Not piston SH. · ABCD: Communicating to the Infinity indoor / 59MN7 family. D is not Y.
If fail: Stay on this plate. The out-of-range reading is the part.
If pass: Reading in range → the next step in this workflow is the repair.
Test points
Charge
Recover and weigh. Nameplate + ounces/ft. Not piston SH.
ABCD
Communicating to the Infinity indoor / 59MN7 family. D is not Y.
Drive
Inverter LEDs / last fault. No contactor coil 24 VAC test.
Gotchas
- RA20 on an older invoice is this inverter family. Confirm 410A vs R-454B before you recover.
Related plates
Install this plate
Install Rheem RA19AY as Prestige / Endeavor · inverter AC.
Prestige / Endeavor · inverter AC
This plate — not the sister SKU
- Not RA17 / RA17AZ two-stage. Not RA16 / RA14AZ contactor. Not a heat-pump RP series (RV + defrost).
- RA20 on an older invoice is this inverter family. Confirm 410A vs R-454B before you recover.
Control on this outdoor
- EcoNet events / outdoor drive. Indoor 45/46 is the furnace.
- No dual cap. No defrost.
- RA20 vs RA19AY — same inverter idea, read the refrigerant letter.
Hardware
- Drive: Inverter scroll · variable capacity
- Bus: EcoNet when the indoor talks; 24V on mixed jobs
- Charge: Weigh-in + line-set. Match the nameplate refrigerant.
First fire
- 1Drive / EcoNet events. No contactor to chase.
- 2Weigh-in on the refrigerant that is on THIS plate.
- 3RP / heat-pump twins have an RV. This AC does not.
Do not on Rheem RA19AY
- Not RA17 / RA17AZ two-stage. Not RA16 / RA14AZ contactor. Not a heat-pump RP series (RV + defrost).
- RA20 on an older invoice is this inverter family. Confirm 410A vs R-454B before you recover.
Maker literature
FieldBench does not host manufacturer files. Each link opens the maker’s own literature page in a new tab.
- Rheem residential furnacesLiterature searchR96T / R96V / R801V / R802V / R98MV product cards. I/O is typically MyRheem / PTS dealer.Open manufacturer PDF
- Rheem supportLiterature searchOwner docs and registration. Full I/O is not hosted as a public PDF for most Endeavor plates.Open manufacturer PDF
Warranty and bulletins
Affected models, serial range, symptom, remedy, date. Maker files open on the manufacturer site.
Residential limited warranty
dealerRheem furnace warranty
Registered Endeavor / Classic furnace warranty · Dealer claims portal
Dealer portals
dealerWhere remaining service letters live
Current-year service letters not on a public literature page · Maker dealer portal