Carrier
59SP6 Furnace · Performance 96 · single-stage · variable-speed
Carrier Performance single-stage VS 96% (59SP6 current, 59SP5 previous). One solenoid, one PS, VS / 25-speed blower. Two-digit IFC. 32 is not low-fire — there is no high fire. Bryant twin is 926S.
Not 59TP6 / 59TP7 (two-stage, dual PS, W2). Not 59SC5 / 59SC6 Comfort (no Performance VS plug story). Not Infinity.
Walk this in Diagnose This plate
AFUE Up to 96–97% single-stage condensing
Staging Single-stage · one PS
Blower VS / 25-speed · setup, not a TP6 two-stage plug map
Sister SKU Bryant 926S · 59SP5 previous Performance single-stage This board Preferred two-digit IFC · single-stage
Same 11–14, 21–24, 31, 33, 34, 41, 45 family as other Bryant/Carrier two-digit boards. One draft switch. 31 is that switch. Door-card 32, if printed, is still the only PS — not a 926T low-fire path. No W2 furnace terminal that means high fire. A leftover W2 is unused or an AC stage. Sequence W. Inducer → single PS must close (31 if not) → HSI → valve → flame (34) → VS blower. No W2 path. There is no high-fire prove and no second solenoid. Faults on this IFC 13 / 33
Limit / lockout warn Airflow or rollout. 13 is the hardened 33.
VS heat CFM / setup — not a 9-speed tap. Filter, coil, return. Rollout is manual reset. 14 / 34
Ignition lockout No flame prove. 14 is the hardened 34.
24
Fuse warn 24 V fuse open.
Tstat short, HUM/EAC, valve harness. 31
PS / draft lockout The only pressure switch did not close.
Trap, collector, PVC, wind, inducer. One hose, one switch. Do not hunt a high-fire hose. 41 / 44
Blower RPM / calibration lockout VS motor vs setup.
Static, filter, correct setup for the coil tons. 45
Control lockout lockout IFC parked. Not Rheem 45.
Find the root two-digit first. Workflows 31 on 59SP6 Inducer running, no light.
One pressure switch. Do not pull a 59TP6 dual-hose card. Trap / PVC / attic ice — still 96% condensing. 59SC5 is Comfort, not this Performance VS motor. Test points
Pressure switch One NO switch. Closed only after inducer is up.
Manifold Single-stage plate value — no low/high pair. Gotchas 59SP5 was incorrectly aliased under 59TP6. It is single-stage. This is the correct plate. 59SC6 18-speed Comfort is not this Performance VS IFC. Terms Privacy Refund policy FieldBench is an independent reference tool and is not affiliated with, authorized by, or endorsed by Goodman, Amana, Daikin, Carrier, Bryant, or any equipment manufacturer. All product names and model numbers are trademarks of their respective owners, used for identification only.